DESIGNATION MARKERS (P-Touch)
a) Designation markers shall be ½” to 1 inch in width tape, not to exceed 3 inches in length.
b) All markers shall be white with black lettering
c) A designation marker shall not overlap itself.
d) Multi-strand waxed cord shall not be used to affix a marker.
e) Designations on ¾ to 1 inch markers shall be sized to allow for all information needed but shall be no smaller than 1/16 inch.
f) Designations on ½ inch markers shall be sized to allow for all information needed but shall be no smaller than 1/16 inch.
g) A designation marker on ½ inch tape shall have no more than 3 lines of information.
h) Designation markers shall be installed so they are visible and legible. Markers must be staggered at high density applications to achieve visibility.
i) Longitudinal markers can be used for ½” or larger coax cable & outdoor deployments.
1. Cables identified with longitudinal markers shall have longitudinal markers at each end.
2. Longitudinal markers shall have the information positioned so that the information can be read without having to twist the ca ble.
3. Longitudinal markers shall be of a self laminating type to prevent the label from peeling and the marker shall be protected w ith clear heat shrink.
j) Labels shall be placed so that they do not peel or lift but remain permanently affixed.
k) All designations shall have the correct information, be at the proper location, be legible from a normal distance and viewing position, and be the proper color.
l) All designations shall be properly aligned and spaced.
m) Designations shall not be hand written.
n) Designations will be placed on smooth surfaces only.
Outdoor Deployments
a) Will use a combination of outdoor rated labels/tags.
1. Longitudinal markers with clear heat shrink for power, grounding & coax cables.
2. Vinyl labels/placards for cabinets & RRH’s.
Rack Labeling I Antenna Solutions Group
RR 1 RR 2
RR 3
PP 1
Rack labels will include
Relay Rack (n).
Power Plant Battery Rack Relay Rack
Example Example Example
AC Power Equipment Labeling I Antenna Solutions Group
Transformer labels will include AC Panel labels will include AC Breaker labels will include
- Line 1: AT&T – Transformer (n) - Line 1: AT&T – Power Service Cabinet (n) Breaker destination
- Line 2: kVA – in Voltage - Line 2: Voltage – phase/type of service
- Line 3: Out voltage – phase - Line 3: Amps
- Line 4: To PSC (n)
AT&T – PSC 1
120V/208V – 3P/4W
200A
PP 1
Spare
REC 1
PP 1
Spare
REC 2
PP 1
Spare
REC 3
PP 1
Spare
REC 4
PP 1
Spare
REC 5
PP 1
Spare
AT&T – TRF 1 REC 6
45 kVA - 480V PP 1
Spare
120V/208V 3P REC 7
To PSC 1 PP 1
Spare
REC 8
PP 1
Spare
REC 9
Spare Spare
Transformer Example AC Panel Example AC Breaker Example
DC Power Equipment Labeling I Antenna Solutions Group
Power Plants
Alpha, Emerson & GE
Example
All labels will include the following
Power Plant (n) PP 1
Fuse Panels Example Power Distribution Units Example
- Westell & Delta Commscope PDU PDU 1
FP 1
All labels will include the following All labels will include the following
Fuse Panel (n) Power Distribution Unit (n)
Line Power Panels Example
Alpha – eLimiter Power Supply Units Example
GE – Power Express & DC/DC Converter LP 1 Commscope PSU & TE PSU PSU 1
All labels will include the following All labels will include the following
Line Power (n) Power Supply Unit (n)
Power Cable Labeling I Antenna Solutions Group
All Power Cables will be identified with a P-Touch label on a 145 tag and secured with multi-strand waxed cord,
with a sufficient pigtail to allow the tag to be rotated for viewing.
At The Source, Battery (+) & Return (-)
- Line 1: Load Name – Load Location
- Line 2: “BATT” or “RET”
At The Load, Battery (+) & Return (-)
- Line 1: Source Name (Power Plant, Fuse Panel or PSC) – Source Location (Relay Rack (n) )
- Line 2: Breaker Position or Fuse Position
- Line 3: “BATT” or “RET”
Power Cable Example
DC Power Plant in PP 1 – RR 1 FP 1 – RR 2
FP 1 – RR 2 MH 1 – RR 2
BP 1 FUSE 1
relay rack #1 “BAT”
“BAT”
Fuse Panel in “BAT” DAS Main Host in
“BAT”
relay rack #2 relay rack #2
+ + + +
FP 1 MH 1 – SEC 1
PP 1 - - - -
PP 1 – RR 1 FP 1 – RR 2
FP 1 – RR 2 MH 1 – RR 2
BP 1 FUSE 1
“RET” “RET”
“RET” “RET”
Grounding Labeling at MGB I Antenna Solutions Group
All grounding cables will be identified with a P-Touch label on a 145 tag and secured with multi-strand waxed
cord, with a sufficient pigtail to allow the tag to be rotated for viewing.
Main Ground Conductor (MGC) – Will be labeled “MGB TO EARTH GROUND - DO NOT REMOVE”.
Ground Cables – Will be identified at the MGB with its origin and destination.
MGB – Will be identified with minimum 3/4 inch letters by way of stamping, stenciling or a designation plate,
easily visible from the floor.
MGB
MGB TO MGB TO
EARTH GROUND UMTS RRU
DO NOT REMOVE CCU4639 X/T
BTS Equipment Labeling I Antenna Solutions Group
All labels will include
- Line 1: Site ID (from RFDS).
- Line 2: Technology, frequency & DAS sector.
Cabinet Example
CVL03012-7R-1-DB
LTE 700 SEC 1
CVL03012-7R-1-DB
LTE 700 SEC 1
BBU Example
RRH Example
BTS/DAS POI Cable Labeling I Antenna Solutions Group
All BTS cables will include All DAS POI cables will include
- Line 1: Site ID (from RFDS) - Line 1 DAS POI Side: Main Host (n)
- Line 2: Technology, frequency & DAS sector - Line 1 Main Host Side: POI (n)
- Line 3: Destination (coax only) - Line 2: Technology, frequency & UL or DL
- Line 3: DAS Sector
BTS/DAS POI Cable Example
RRH
MH 1 POI 1
CCU4639 X/T UMTS 850 UL UMTS 850 UL
UMTS 850 SEC 1 SEC 1 SEC 1
DAS POI Tray
POI 1 MH 1 – SEC 1
CVU4639 X/T CVU4639 X/T
UMTS 850 SEC 1 UMTS 850 SEC 1
POI 1 MH 1 POI 1 DAS Main Host
CVU4639 X/T UMTS 850 DL UMTS 850 DL
UMTS 850 SEC 1 SEC 1 SEC 1
DAS Equipment Labeling I Antenna Solutions Group
If equipment (shelf or card) is carrier Example Optical Trays/Cards
specific an extra label will be required MA – BU4, BU8, FT350 OCH Example
ATT Commscope – TFLN, OTRx
OPT 1 – S
All labels will include the following TE – SeRF II Module
ATT, VZW, TMO, SPT
All labels will include the following
OPT (n) – Siso or Mimo
DAS POI Trays Example
- Westell, CCI, AIP, PAU6 & i-POI
POI 1 Expansion Hubs Example
All labels will include the following TE – Spectrum & Fusion
EH 1 – MH 1
Point Of Interface (n)
All labels will include the following
Expansion Hub (n) – Main Host Feed (n)
DAS Hosts Example
TE – Prism, Spectrum, Amp Chassis, Fusion Amplifier Chassis
MH 1 – SEC 1 Example
MA – RIU4, RIU12 TE – Host To Host Amplifier Chassis
Commscope – TPRN, ION-U MH 1 – AC 1
All labels will include the following
All labels will include the following Main Host (n) – Amplifier Chassis (n)
Main Host (n) – Sector (n)
DAS Remotes Example
System Controllers Example TE – Prism & RAU
MA – SC450 MA – MA1000, MA2000, HX, QX & GX RU 1 - S
Commscope – RMC1600, TSUN SC 1 Commscope – ION-B, ION-U & ION-M
All labels will include the following All labels will include the following
System Controller (n) Remote Unit (n) – Siso or Mimo
Alarming & Backhaul Equipment Labeling I Antenna Solutions Group
SIADs Example
Cisco & ALU
BH 1 - WSCRCA030AW Antennas, BOTS, Couplers & Splitters/
All labels will include the following
Back Haul (n) – CLLI Code
Combiners Labeling
DAS Router Example Antennas Example
Cisco
DR 1 1–M
All labels will include the following
All labels will include the following Antenna (n) – SISO or MIMO
DAS Router (n)
SNMP Switch Example BOTS Example
Cisco SNMP 1 BOT 1
All labels will include the following
All labels will include the following BOT (n)
Simple Network Management Protocol (n)
BOT Switch Example
Splitters/Combiners Example
Cisco, Dantel EB 1 SC 1
All labels will include the following
All labels will include the following
Splitter/Combiner (n)
Echo BOT (n)
Power Plant Alarming Example Couplers Example
WebMon PPA 1 CP 1
All labels will include the following
All labels will include the following Coupler (n) – Sector (n)
Power Plant Alarming (n)
Remote/Antenna Cable Labeling I Antenna Solutions Group
Remote side/Splitter Output labels will include Antenna side/Splitter Input labels will include
Antenna Destination(s), SISO or MIMO Remote Feed, SISO or MIMO
Antenna/Remote Cable Example
ANT 3 - S
ANT 2, 3 - S RU 1 - S
RU 1 -S
SC 2
SC 1
ANT 2 - S
ANT 1, 2, 3 - S ANT 1 - S
RU 1 - S RU 1 - S RU 1 - S
RU 1 - S
1-S 2-S 3-S
DAS Remote DAS Antenna DAS Antenna DAS Antenna
Fiber Panel Labeling I Antenna Solutions Group
Fiber Panel Example
IDF 1 Assignment Card IDF 2 Assignment Card
All labels will include the following
- Line 1: Fiber Panel (n)
- Line 2: ATTDAS, cable count (n) – (n) IDF 1 Fiber Panel IDF 2 Fiber Panel
FP 2 FP 3
Manufacturer provided assignment card will ATTDAS, 1-12 ATTDAS, 13-24
be filled out with Remote Unit Destinations
(If no card is provided, P-Touch will be used) AT T DAS, 1-12
FP 1
AT T DAS, 13-24
FP 1
Head End
Assignment Card
Head End Fiber Panel AT T DAS, 1-12
FP 2
FP 1
ATTDAS, 1-24 AT T DAS, 13-24
FP 3
Fiber Cable Labeling I Antenna Solutions Group
Head End labels will include IDF labels will include
Line 1: ATTDAS, cable count (n) – (n) Line 1: ATTDAS, cable count (n) – (n)
Line 2: Destination FP (n) Line 2 IDF: From Fiber Panel (n)
IDF 1 Fiber Panel
FP 2
ATTDAS, 1-12
Fiber Cable Example
ATTDAS, 1-12
FP 1
ATTDAS, 1-12
FP 2
FP1
ATTDAS, 13-24
ATTDAS, 1-24 FP 1
ATTDAS, 13-24
Head End Fiber Panel FP 3
FP 3
ATTDAS, 13-24
IDF 2 Fiber Panel
Fiber Jumper Labeling I Antenna Solutions Group
| Last Resume Update | September 5, 2016 |
| Address | Greensboro |
Locked | |
| Resume File | ATT-Labeling_42814.pdf 514.44 kB |

Locked